3KVA, On Grid Inverter
Our USP:
| Superior Performance |
| In-built global MPP scan for higher yield efficiency |
| Assured Safety & Reliability |
| User Friendly Monitoring |
| Superb Adaptability |
PRONTO RENEWABLES ENERGY PVT LTD | ||
| PRONTO ON GRID INVERTER VAYU SERIES - SPECIFICATIONS | ||
| INVERTER RATING (KVA) | 3KVA | |
| A | DC Input | |
| 1 | Max. PV array input power [Wp] | 6000 |
| 2 | Max. PV input voltage [V] | 550 |
| 3 | Startup voltage [V] | 50 |
| 4 | Nominal input voltage [V] | 360 |
| 5 | MPP tracker voltage range [V] | 40~550 |
| 6 | No. of MPP trackers / Strings per MPP tracker | 1 |
| 7 | Max. PV input current [A] | 16A |
| 8 | Isc PV Array Short Circuit current [A] | 22A |
| B | AC OUTPUT | |
| 1 | Rated AC output power [W] | 3000 |
| 2 | Rated AC output current [A] | 13.1 |
| 3 | Max. AC output apparent power [VA] | 3300 |
| 4 | Max. AC output current [A] | 15 |
| 5 | Nominal AC voltage/AC voltage range [V]** | 220/230/240, 90~290 |
| 6 | Nominal AC frequency/AC frequency range [Hz]** | 50/60±5 |
| 7 | Power Factor range | 0.8 leading ~ 0.8 lagging |
| 8 | THDi (Rated power) [%] | <3 |
| B | SYSTEM DATA | |
| 1 | Max. efficiency [%] | 98 |
| 2 | Euro. efficiency [%] | 97 |
| 3 | Standby consumption [W] @Night | <1 |
| 4 | Ingress protection | IP66 |
| 5 | Protection class | Class I |
| 6 | Over voltage category | II (DC), III(AC) |
| 7 | Max. operation altitude [m] | <4000 |
| 8 | Humidity [%] | 0~100 |
| 9 | Typical noise emission [dB] | 25 |
| 10 | Dimensions (W×H×D) [mm] | 290×206×120 |
| 11 | Weight [kg] | 5.5 |
| 12 | Cooling concept | Natural cooling |
| 13 | Communication interfaces | USB/RS485/DRM, Optional: Meter/CT |
| 14 | Optional monitoring dongle | Pocket WiFi/LAN/4G |
| 15 | Display | 2 × LED + LCD (16 × 2) / APP |
| C | PROTECTION | |
| 1 | Over/under voltage protection | Yes |
| 2 | DC isolation protection | Yes |
| 3 | Monitoring ground fault protection | Yes |
| 4 | Grid monitoring | Yes |
| 5 | DC injection monitoring | Yes |
| 6 | Back feed current monitoring | Yes |
| 7 | Residual current detection | Yes |
| 8 | Anti-islanding protection | Yes |
| 9 | Over temperature protection | Yes |
| 10 | SPD (DC/AC) | Type II / Type II (Optional) |
| 11 | Arc-fault circuit interrupter (AFCI | Optional |
| 12 | AC auxiliary power supply (APS) | Optional |
| 13 | DC Switch | Optional |
| D | STANDARD | |
| 1 | Safety | EN/IEC62109-1/2 |
| 2 | EMC | EN61000-6-1/2/3/4; EN61000-3-2/3/11/12 |
| 3 | Certification | IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105, CEI 0-21, VFR |
| Note: | ||
| * Not included in the package. Please purchase additionally. | ||
| **The AC voltage and the frequency range may vary from different country codes | ||
| The specifications & Design are subject to change due to continuous improvements. | ||