5KVA, ON Grid Inverter
Our USP:
| Superior Performance |
| In-built global MPP scan for higher yield efficiency |
| Assured Safety & Reliability |
| User Friendly Monitoring |
| Superb Adaptability |
PRONTO RENEWABLES ENERGY PVT LTD | ||
| PRONTO ON GRID INVERTER VAYU SERIES - SPECIFICATIONS | ||
| INVERTER RATING (KVA) | 5KVA | |
| A | DC Input | |
| 1 | Max. PV array input power [Wp] | 10000 |
| 2 | Max. PV input voltage [V] | 600 |
| 3 | Startup voltage [V] | 50 |
| 4 | Nominal input voltage [V] | 360 |
| 5 | MPP tracker voltage range [V] | 40~560 |
| 6 | No. of MPP trackers / Strings per MPP tracker | 2 /1 |
| 7 | Max. PV input current [A] | 16/ 16 |
| 8 | Isc PV Array Short Circuit current [A] | 22/ 22 |
| B | AC OUTPUT | |
| 1 | Rated AC output power [W] | 5000 |
| 2 | Rated AC output current [A] | 21.7 |
| 3 | Max. AC output apparent power [VA] | 5000 |
| 4 | Max. AC output current [A] | 21.7 |
| 5 | Nominal AC voltage/AC voltage range [V]** | 220/230/240, 90~290 |
| 6 | Nominal AC frequency/AC frequency range [Hz]** | 50/60±5 |
| 7 | Power Factor range | 0.8 leading ~ 0.8 lagging |
| 8 | THDi (Rated power) [%] | <3 |
| B | SYSTEM DATA | |
| 1 | Max. efficiency [%] | 98 |
| 2 | Euro. efficiency [%] | 97 |
| 3 | Standby consumption [W] @Night | <3 |
| 4 | Ingress protection | IP66 |
| 5 | Operating ambient temperature[°C] | -25~60 |
| 8 | Max. operation altitude [m] | 4000 |
| 9 | Humidity [%] | 0~100 |
| 10 | Typical noise emission [dB] | 25 |
| 11 | Storage Temperature [°C] | -30~70 |
| 12 | Dimensions (W×H×D) [mm] | 404×274×146 |
| 13 | Weight [kg] | 11 |
| 14 | Cooling concept | Natural cooling |
| 15 | Communication interfaces | USB/RS485/DRM, Optional: Meter/CT |
| 16 | Optional monitoring dongle | Pocket WiFi/LAN/4G |
| 17 | Display | 2 × LED + LCD (16 × 2) / APP |
| C | PROTECTION | |
| 1 | Over/under voltage protection | Yes |
| 2 | DC isolation protection | Yes |
| 3 | Monitoring ground fault protection | Yes |
| 4 | Grid monitoring | Yes |
| 5 | DC injection monitoring | Yes |
| 6 | Back feed current monitoring | Yes |
| 7 | Residual current detection | Yes |
| 8 | Anti-islanding protection | Yes |
| 9 | Over temperature protection | Yes |
| 10 | SPD (DC/AC) | TypeII / TypeII (Optional) |
| 11 | Arc-fault circuit interrupter (AFCI | Optional |
| 12 | AC auxiliary power supply (APS) | Optional |
| 13 | DC Switch | Optional |
| D | STANDARD | |
| 1 | Safety | EN/IEC62109-1/2 |
| 2 | EMC | EN61000-6-1/2/3/4; EN61000-3-2/3/11/12 |
| 3 | Certification | IEC61727, EN50549, G98/G99, AS 4777.2, VDE4105, CEI 0-21, VFR |