PRATHVI 24V (2KVA-3KVA)
Our USP:
- Zero Volt Pickup
- Ready For Lithium
- Four Charging Profile for Lithium
- Mains Reverse Feed Protected
- Designed For Heavy Load according to Models Rating
- Low consumption (electrolytic / acid) Technology
- Optional Remote Monitoring Available
- Power Saving Technology (Inverter Cost is recovered in 3-4 Years) Optional
PRONTO RENEWABLES ENERGY PVT LTD | |||||
| PRATHVI SERIES - NON SOLAR (HOME UPS) - SPECIFICATIONS | |||||
| INVERTER RATING (KVA) | 2000VA | 2500VA | 3000VA | ||
| BATTERY VOLTAGE | 24 | 24 | 24 | ||
| DESIGN | LOW FREQ. TRANSFORMER BASED DESIGN | ||||
| USP OF THE PRODUCT | LITHIUM COMPATIBLE READY FOR LITHIUM,LOW ELECTROLYTIC/ACID CONSUMPTION TECHNOLOGY,LEAD ACID BATTERY EQUALISATION MODE,VOLTAGE REGULATION UPTO 165V OPTIONAL | ||||
| LITHIUM COMPATIBLE (LITHIUM SPECIAL) | 4 TYPE CHARGING PROFILE FOR LITHIUM BATTERY | ||||
| A | INVERTER/ SOLAR PCU | ||||
| 1 | No. of Phases/Connection Type | 1Phase/2wire | |||
| 2 | Nominal Output Voltage/Frequency (Volts/Hz) | 220/50hz | 220/50hz | 220/50hz | |
| 3 | Nominal VA Capacity (VA) | 2000 | 2500 | 3000 | |
| 4 | INVERTER LOAD Capacity (W) (BULB LOAD) | 1.6KW | 2KW | 2.4KW | |
| 5 | Battery Discharging Full Load Current (A) | 66 | 83 | 100 | |
| 6 | Voltage Regulation (At No Load) | ±2% | ±2% | ±2% | |
| 7 | Freq Regulation (At No Load) | ±0.5 Hz | ±0.5 Hz | ±0.5 Hz | |
| 8 | THD | <4% | >4% | >4% | |
| 9 | Load Power Factor | 0.8 lag lag to unity | |||
| 10 | Over Loads ** : | 100-105% - 60 sec | |||
| 11 | 105-110% - 30 sec | ||||
| 12 | 110-120% - 2 sec | ||||
| B | BATTERY HIGH/LOW CUT VOLTAGE | ||||
| 1 | Lithium (LFP) Low Batt. Alarm | PROFILE-1 | 22.8 | 22.8 | 22.8 |
| 2 | Lithium (LFP) Low Batt. Cut | 22.4 | 22.4 | 22.4 | |
| 3 | Lithium (LFP) High Batt./full Charge Cut | 27.6 | 27.6 | 27.6 | |
| 4 | Lithium (LFP) Low Batt. Alarm | PROFILE-2 | 22.8 | 22.8 | 22.8 |
| 5 | Lithium (LFP) Low Batt. Cut | 22.4 | 22.4 | 22.4 | |
| 6 | Lithium (LFP) High Batt./full Charge Cut | 28 | 28 | 28 | |
| 7 | Lithium (LFP) Low Batt. Alarm | PROFILE-3 | 22.8 | 22.8 | 22.8 |
| 8 | Lithium (LFP) Low Batt. Cut | 22.4 | 22.4 | 22.4 | |
| 9 | Lithium (LFP) High Batt./full Charge Cut | 28.4 | 28.4 | 28.4 | |
| 10 | Lithium (LFP) Low Batt. Alarm | PROFILE-4 | 22.8 | 22.8 | 22.8 |
| 11 | Lithium (LFP) Low Batt. Cut | 22.4 | 22.4 | 22.4 | |
| 12 | Lithium (LFP) High Batt./full Charge Cut | 28.8 | 28.8 | 28.8 | |
| 13 | Tubular Low Batt. Alarm | TUBULAR | 21.6 | 21.6 | 21.6 |
| 14 | Tubular Low Batt. Cut | 21 | 21 | 21 | |
| 15 | Tubular High Batt./full Charge Cut | 28.8 | 28.8 | 28.8 | |
| 16 | SMF Low Batt. Alarm | SMF/VRLA | 21.6 | 21.6 | 21.6 |
| 17 | SMF Low Batt. Cut | 21 | 21 | 21 | |
| 18 | SMF High Batt./full Charge Cut | 28 | 28 | 28 | |
| C | GRID CHARGER | ||||
| 1 | Grid Voltage Range (Inverter Mode) | 90V-280V (PHASE TO NEUTRAL) | |||
| 2 | Grid Voltage Range (UPS Mode) | 180V-265V (PHASE TO NEUTRAL) | |||
| 3 | Grid Frequency Range (Freq.Sync.Range) | 50 Hz ± 5% | |||
| 4 | Max Battery Amps During Grid Charging (Amps) | 16A | 16A | 16A | |